Features:
1. The separation of humidifier system from electric circuit improves safety and protects the circuit against the leakage of water supply line.
2. LCD touch screen, available in English, easy to operate and program.
3. With external water supply system, convenient to supplement the cylinder water supply, and automatic recovery using.
4. Control temperature humidity well-distributed, precisely and steady.
5. Door bunk isolated airtight packing, can be effectively isolated from the internal temperature of the leak.
6. Built-in mobile wheels allow easy movement and placed and have a strong positioning screw position.
Specification:
Description
|
Programmable temperature humidity chamber
|
Model
|
YTH-080
|
YTH-150
|
YTH-225
|
YTH-408
|
YTH-800
|
YTH-1000
|
Inner chamber size
( W×H×D(mm))
|
400×500×400
|
500×600×500
|
500×750×600
|
600×850×800
|
1000×1000×800
|
1000×1000×1000
|
Exterior chamber size
( W×H×D(mm))
|
900×900×1500
|
950×1500×1050
|
950×1650×1150
|
1050×1750×1350
|
1450×1900×1350
|
1450×1900×1550
|
Temperature Range
|
‘-73℃ -60℃, -40℃, -20℃, 0℃~+150℃, +180℃
|
Humidity Range
|
20%HR ~98%HR
|
|
|
|
|
|
|
|
0.3℃, ±0.5%RH
|
Temp. and Humi.uniformity
|
1.5℃,2.5% RH when RH more than 75%,4% RH when RH less than 75% (tested with the empty chamber, 30 minutes after stabilization)
|
Temp. and humi. Resolution
|
0.01℃,0.1%RH
|
Heat up time(20℃~high temp.)
|
Temperature
|
100 150
|
100 150
|
100 150
|
100 150
|
100 150
|
100 150
|
minutes
|
30 40
|
30 40
|
30 45
|
30 45
|
30 45
|
30 45
|
Cool down time(20℃~low temp.)
|
Temperature
|
0 -20 -40 -60 -70
|
0 -20 -40 -60 -70
|
0 -20 -40 -60 -70
|
0 -20 -40 -60 -70
|
0 -20 -40 -60 -70
|
0 -20 -40 -60 -70
|
minutes
|
25 40 50 70 80
|
25 40 50 70 80
|
25 40 50 70 80
|
25 40 55 70 80
|
25 40 65 75 85
|
25 40 65 75 85
|
Exterior chamber material
|
Stainless steel plate+Powder Coated
|
Interior chamber material
|
SUS#304 stainless steel plate
|
Insulation
|
PU & Fiberglass wool
|
Wind Circulation
|
Sirocco fan
|
Heating system
|
SUS#304 stainless steel high-speed heater
|
Humidifying
|
Surface evaporating system
|
Cooling
|
Imported compressor, finned type evaporator ,air-cooling condenser
|
Dehumidifying
|
ADP critical dewpoint cooling/dehumidifying method
|
Controller
|
Digital electronic indicators +S.S.R. With PID automatic calculation capability
|
Other Components
|
Vacuum glass inspection window, cable port(60mm),control status indicator lights, chamber
|
Lamp ,loading shelves (2pcs for free)
|
Safety Devices
|
Overheating circuit-breaker, compressor overload protection, control system overload protection, humidifying system overheating protection, breakdown indicator light
|
Power supply
|
AC 1∮ 220V;3∮380V 60/50Hz
|