Technical Parameters
Voltage and current measurement ranges
|
Output capacity
|
Output voltages
|
57.7V/163.5V/220V/240V/480V
|
Voltage loop : Max.50VA
|
Output currents
|
0.1A、1A、5A、 20A、 100A
|
Current loop :Max.100VA (for measurement range of 100A)
|
Output electric quantity adjustment
|
Adjustment range
|
Adjustment fineness
|
Max.output voltage/current
|
Voltage adjustment
|
0%-125% of each shift value
|
10%,1%, 0.1%,and 0.01% for your option
|
300V or 600v
|
Currents adjustment
|
0%-125% of each shift value
|
10%,1%, 0.1%,and 0.01% for your option
|
120A
|
Phase adjustment
|
0°-359.99°
|
10%,1%, 0.1%,and 0.01% for your option
|
|
1. Accuracy :Output voltage. current, and power: Grade 0.2 (Embedded standard watt- hour meter)
2. Output voltage and current distortion Output voltage and current distortion not larger than 0.3%
3. Output power stability The variation of pre-set output power :not more than 0.02%(180S)
4. Electric quantity symmetry among the three phases
The difference between any line voltage or phase voltage and its mean value will not be larger than 0.2%; the difference between any phase current and its mean value will not be larger than 0.2%: the phase difference between any phase current and its corresponding phase voltage will not be large than 0.2°
5. Harmonic wave setting
◆ Number of harmonic wave:2-31
◆ Content of harmonic wave: less than 40% (compared with base wave)
◆ Phase of harmonic wave:0° - 359.99°
6. Monitoring instrument
A. (Embedded standard watt-hour meter) monitoring Instrument' s accuracy grade and resolution: Current and voltage:±0.1%; Phase: ±0.1° ;Frequency: ±0.01Hz
B. (Insert- type standard watt- hour meter) reading will be made directly from the standard watt- hour meter
7. Power supply :AC single-phase 220/240 (100V/110V also available). 50/60Hz. maximum input power consumptlon:500W
8. Outer dimensions: 510 x 540 x 200mm