Product Description
It composes of high-stability single-phase program-controlled power source and single-phase standard watt-hour meter. It applies to the calibration of electronic and electro-mechanical single-phase active and reactive watt-hour meters as well as multi-function watt- hour meters and can provide us with rich electric quantity information such as AC voltage. AC current, phase difference between voltage and current, power factor, active power, reactive power, apparent power, frequency and so on. It can be used in such area as product research and development, product maintenance, and product test at production lines. By using the underlying dynamic link library users may develop their own automatic meter calibration software.
Technical Parameters
Output voltage and current measurement ranges
|
Output capacity
|
Output voltages
|
220V
|
Voltage loop :Max.50VA
|
Output voltages
|
0.1A,1A,5A,20A,100A
|
Current loop :Max.100VAv
|
Output electric quantity adjustment
|
Adjustment range
|
Adjustment fineness
|
Voltage adjustment
|
0%-125% of each shift value
|
10%,1%, 0.1%,and 0.01% for your option
|
Current adjustment
|
0%-125% of each shift value
|
10%,1%, 0.1%,and 0.01% for your option
|
Phase adjustment
|
0°-359.99°
|
10%,1%, 0.1%,and 0.01% for your option
|
1. Output voltage and current distortion ≤ 0.3% (If it is a linear load)
2. Output power stability ≤0.02% (180s ) compared with the measurement range
3. Harmonic wave setting
◆ Number of harmonic wave:2- 31
◆ Content of harmonic wave: ≤40% (compared with base wave}
◆ Phase of harmonic wave:0°~359 .99°
4. Monitoring instrument :Reading will be made directly from the standard watt-hour meter
5. Embedded with three error processors
6. Power supply: AC 220/240 (100V/110V optional), 50/60Hz, maximum input power consumption:500W
7. Outer dimensions: 510x200mm